NutriChef Dual-Zone Separation / Airflow Fault

Temperature between upper and lower zones is not different; both zones stay at similar temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed partition fan or damper, Air leak between zones, Single cooling module not distributing correctly, Thermistor misplacement between zones

How to Fix / Troubleshooting

Safety: Unplug the cooler before removing internal panels.

Steps:

  • 1. Confirm design: Verify that your NutriChef model is truly dual-zone and not a single-zone with separate displays.
  • 2. Inspect partition: Check the divider between zones for gaps or missing foam that could allow uncontrolled air mixing.
  • 3. Check zone fans/dampers: Access the internal ducting and verify that any zone-specific fans or dampers operate when each zone calls for cooling. Replace failed fans.
  • 4. Verify sensor locations: Ensure each zone's thermistor is in the correct compartment and not swapped or dangling.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Zone Partition Fan / Damper