NutriChef
Dual-Zone Separation / Airflow Fault
Temperature between upper and lower zones is not different; both zones stay at similar temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed partition fan or damper, Air leak between zones, Single cooling module not distributing correctly, Thermistor misplacement between zones
How to Fix / Troubleshooting
Safety: Unplug the cooler before removing internal panels.
Steps:
- 1. Confirm design: Verify that your NutriChef model is truly dual-zone and not a single-zone with separate displays.
- 2. Inspect partition: Check the divider between zones for gaps or missing foam that could allow uncontrolled air mixing.
- 3. Check zone fans/dampers: Access the internal ducting and verify that any zone-specific fans or dampers operate when each zone calls for cooling. Replace failed fans.
- 4. Verify sensor locations: Ensure each zone's thermistor is in the correct compartment and not swapped or dangling.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Zone Partition Fan / Damper
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements