NutriChef Temperature Calibration / Sensor Accuracy Issue

Temperature display does not match actual temperature inside by more than 5–10°F.

Advertisements

Possible Causes

Aging thermistor, Sensor not in representative air location, Control board calibration drift

How to Fix / Troubleshooting

Safety: Unplug before moving sensors or accessing the board.

Steps:

  • 1. Verify with reliable thermometer: Place a calibrated thermometer in the center of the cabinet and compare readings after several hours.
  • 2. Adjust set point: Compensate by adjusting the set temperature up or down to achieve the desired actual temperature.
  • 3. Reposition sensor: Ensure the thermistor is in free air, not touching walls or bottles.
  • 4. Replace thermistor: If discrepancy remains large, replace the cabinet thermistor.
  • 5. Replace control board: Persistent large errors after sensor replacement may indicate a faulty main control board.