C1
Samsung Compressor Current or Load Error

Display shows C1 and the compressor may run continuously or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overloaded compressor due to high ambient temperature, Failing compressor drawing excessive current, Faulty current sensor on main PCB, Blocked condenser airflow

How to Fix / Troubleshooting

Safety first: Unplug the wine cooler before accessing the compressor or control board.

  • 1. Improve ventilation: Ensure the unit has proper clearance and is not installed in a confined cabinet without ventilation. High ambient temperatures can cause high compressor load.
  • 2. Clean condenser: Remove dust and debris from the condenser coils and verify the condenser fan is operating correctly.
  • 3. Listen for compressor noise: A loud, humming, or clicking compressor may indicate mechanical failure. If the compressor is extremely hot to the touch (use caution), it may be overloading.
  • 4. Inspect main PCB current sensor: Some boards use a current-sensing device or shunt resistor. If visibly burnt or cracked, the board should be replaced.
  • 5. Technician diagnosis: Measuring compressor current draw and checking for sealed system restrictions requires specialized tools. Contact a professional if C1 persists after basic airflow and cleaning checks.

Warning: Do not attempt to open or repair the sealed refrigeration system yourself.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board