U1
Samsung
Upper Zone Temperature Sensor Fault
Display shows U1 and the upper zone of a dual-zone Samsung wine cooler is not cooling correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective upper compartment thermistor, Loose upper zone sensor connector, Damaged harness between upper zone and PCB, Main PCB upper sensor channel failure
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing interior panels or the control board.
- 1. Verify upper zone issue: Confirm that the U1 code corresponds to the upper zone and that the upper compartment temperature is inaccurate.
- 2. Locate upper zone sensor: Remove upper shelves and any decorative panel to find the thermistor on the rear or side wall.
- 3. Inspect and secure sensor: Ensure the sensor is firmly attached and not touching cold plates or bottles directly, which can skew readings.
- 4. Check wiring: Trace the sensor harness to the main PCB, looking for damage or loose connectors. Reseat connectors at both ends.
- 5. Test thermistor: Measure resistance and compare to spec. Replace the upper zone thermistor if readings are abnormal.
- 6. Control board evaluation: If the sensor and wiring are good, the main PCB may be misreading the upper zone and require replacement.
Note: After replacing sensors, allow several hours for the temperature display to stabilize.