E13
Siemens
Door Status Logic Error
Display shows E13; interior light remains on or off incorrectly, and door status seems wrong.
Advertisements
Possible Causes
Stuck door switch, Shorted door sensor wiring, Faulty input circuit on main PCB, Incorrect door sensor type after replacement
How to Fix / Troubleshooting
Safety first: Disconnect power before testing the door switch circuit.
Steps to address E13:
- Manually test switch: With the unit unplugged, access the door switch and test continuity with a multimeter while actuating it. It should change state (open/close) reliably.
- Inspect wiring: Look for pinched or shorted wires around the door frame and hinge area.
- Confirm correct part: If the switch was recently replaced, verify that the correct Siemens part number and sensor type (NO/NC or Hall) was used.
- Replace switch: If the switch is intermittent or stuck, install a new door switch / sensor.
If E13 remains, the main PCB may misinterpret the door signal and should be replaced by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch / Sensor
Check Price on Amazon
We may earn a commission from links on this page.