E8
Siemens Control Panel / Touch Keypad Error

Display shows E8; temperature cannot be adjusted or setpoint changes are not accepted.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty touch control panel, Moisture ingress behind control fascia, Loose ribbon cable between display and main PCB, Damaged control PCB

How to Fix / Troubleshooting

Safety first: Disconnect the wine cooler from mains before removing the control panel.

Steps to address E8:

  • Power reset: Unplug for 5–10 minutes, then reconnect. Sometimes E8 is a temporary control lockup.
  • Dry the control area: If the cooler is built-in under a worktop, ensure there is no condensation dripping onto the control panel. Wipe the fascia dry.
  • Remove control fascia: Carefully unclip or unscrew the front control panel. Avoid pulling on the ribbon cable.
  • Inspect connections: Check the ribbon cable and connectors for corrosion, kinks, or partial insertion. Reseat all plugs firmly.
  • Check for damage: Look for burn marks or cracked components on the control PCB.
  • Replace control panel: If the touch keys remain unresponsive or E8 persists, replace the control panel / display PCB with a Siemens-specific part.

If replacing the control panel does not resolve E8, the main control PCB or wiring harness may be at fault and should be evaluated by a technician.

Advertisements

Repair Difficulty

Medium 3/5