E9
Siemens General Sensor Circuit Error / Multiple Sensor Fault

Display shows E9; unit may shut down or run continuously, and temperature readings are clearly incorrect.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Short between sensor wires in harness, Multiple NTC sensors out of range, Damaged wiring loom from door hinge movement, Faulty analog-to-digital converter on main PCB

How to Fix / Troubleshooting

Safety first: Unplug the appliance before inspecting wiring or boards.

Steps to address E9:

  • Visual wiring inspection: Check the main wiring harness from the control panel to the rear of the unit, especially around sharp metal edges and hinge areas. Look for crushed, cut, or melted wires.
  • Check sensor connectors: Reseat all temperature sensor connectors on the main PCB. A poor connection can trigger a general sensor error.
  • Isolate sensors: If you have a multimeter, disconnect each NTC sensor one by one and measure resistance. Replace any that are open or shorted.
  • Repair harness damage: If wires are damaged, repair with proper crimp connectors or replace the affected harness section. Insulate with heat-shrink tubing.

If E9 persists after verifying all sensors and wiring, the main control PCB is likely defective and should be replaced by a qualified technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Wiring Harness or Main Control PCB
Check Price on Amazon