Siemens Overheating Electrical Component

Strong chemical or burning smell coming from the rear of the wine cooler.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overheating main control PCB, Failing compressor start relay, Dust burning on hot condenser, Loose electrical connection arcing

How to Fix / Troubleshooting

Safety first: Immediately unplug the appliance. Do not continue to operate it if a burning smell is present.

Steps to investigate:

  • Inspect rear compartment: After cooling, remove the rear panel and look for discolored or melted components on the main PCB and around the compressor start device.
  • Clean condenser: Remove heavy dust from the condenser coil that may be causing odor when hot.
  • Replace burnt parts: Replace any visibly damaged components such as the compressor start relay or main control PCB.

If you are not experienced with electrical repairs, contact a Siemens service technician immediately.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control PCB / Compressor Start Relay
Check Price on Amazon