Siemens
Thermostat / Sensor Miscalibration
Wine cooler overcools; temperature inside is much lower than setpoint and bottles may be too cold or freezing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Cabinet NTC sensor out of calibration, Sensor not properly positioned, Faulty main control PCB temperature regulation, Ambient sensor reading incorrect
How to Fix / Troubleshooting
Safety first: Unplug the appliance before accessing sensors or control boards.
Steps to correct:
- Verify with thermometer: Place an accurate thermometer inside and compare to the display. Note the difference.
- Check sensor placement: Ensure the cabinet sensor is correctly mounted on the liner wall and not touching the evaporator or a cold air outlet.
- Inspect sensor wiring: Look for damage or loose connections at the sensor and main PCB.
- Replace cabinet sensor: If misreading is large and persistent, replace the cabinet temperature sensor (NTC).
If overcooling continues with a new sensor, the main control PCB may be defective and should be replaced by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature Sensor (NTC Probe)
Check Price on Amazon
We may earn a commission from links on this page.