Siemens Reduced Cooling Capacity / Refrigerant Loss

Wine cooler runs but does not reach set temperature; only slightly cool inside.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge due to micro-leak, Partially blocked capillary tube, Weak compressor, Condenser coil heavily clogged with dust

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning or accessing the rear.

Steps to check:

  • Clean condenser: Remove rear panel and thoroughly clean the condenser coil with a brush and vacuum.
  • Check door seal: Inspect the door gasket for gaps or damage that allow warm air in.
  • Monitor frost pattern: After running for 30–60 minutes, remove the internal rear panel and inspect the evaporator. A healthy system shows even frost across most of the coil. Frost only at the inlet or no frost suggests a sealed-system issue.

If cleaning and gasket checks do not restore proper cooling and the frost pattern is abnormal, the unit likely has a refrigerant or compressor problem that must be addressed by a certified refrigeration technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Condenser Coil / Sealed System Components
Check Price on Amazon