Hi
Simzlife High Temperature Alarm / Sensor Out of Range

Display shows Hi and unit does not cool even though compressor and fans may be running

Advertisements

Possible Causes

Sensor not seated in airflow, Sensor reading ambient instead of cabinet air, Failed NTC sensor

How to Fix / Troubleshooting

Safety: Disconnect power before removing interior panels.

Steps:

  • Door and gasket check: Make sure the door is closing fully and the gasket is sealing. Warm air leaks can trigger Hi alarms.
  • Sensor placement: Remove the interior panel and verify that the sensor probe is positioned correctly in the air stream, not touching the evaporator coil directly or hanging loose.
  • Reposition sensor: Clip or tape the sensor back into its original location if it has moved.
  • Replace sensor: If the sensor is damaged or readings are clearly inaccurate compared to a separate thermometer, replace the NTC sensor.
  • Monitor: After reassembly, allow several hours for the temperature to stabilize and confirm that the Hi code clears.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.