SMEG Unresponsive User Interface

Display is on but buttons or touch controls do not respond, preventing temperature adjustment.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty touch control PCB, Stuck or damaged buttons, Loose ribbon cable to main board, Software lock or child lock mode enabled

How to Fix / Troubleshooting

Safety: Unplug the unit before removing the control panel or touching internal wiring.

Steps to restore control:

  • Check for lock mode: Consult the user manual to see if a child lock or control lock is active. Try the unlock key combination if applicable.
  • Power reset: Disconnect power for 5–10 minutes to reset the control electronics.
  • Inspect control panel: Remove the control bezel and check the touch PCB or button board for moisture, corrosion, or physical damage.
  • Reseat ribbon cable: Disconnect and reconnect the ribbon cable between the UI and main PCB.
  • Replace UI board: If still unresponsive, replace the user interface PCB with a SMEG-compatible part.

Note: Avoid using excessive cleaning liquids on the control panel; moisture can damage touch sensors.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

User Interface / Display PCB
Check Price on Amazon