Possible Causes
Worn evaporator fan motor bearings, Ice buildup around fan blades, Foreign object contacting fan, Loose fan mounting screws
How to Fix / Troubleshooting
Safety: Unplug the appliance before accessing the interior fan. Blades and metal edges can be sharp.
Steps to fix noisy fan:
- Access fan: Remove shelves and the rear interior panel to expose the evaporator fan assembly.
- Check for ice or debris: Remove any ice buildup with warm water and a cloth. Clear any labels, wires, or packing materials that may contact the blades.
- Tighten mounting: Ensure the fan motor and shroud screws are tight.
- Replace fan motor: If noise persists and the motor feels rough when spun by hand, replace the evaporator fan motor with a SMEG-compatible part.
Tip: After reassembly, verify that the fan spins freely and does not touch the shroud.