STAIGIS
Interior LED Lighting Failure
Interior light does not turn on when door is opened, but cooling still works.
Advertisements
Possible Causes
Burned-out LED light module, Faulty door switch or reed sensor, Loose light wiring connector, Failed light driver circuit on main PCB
How to Fix / Troubleshooting
Safety first: Unplug the unit before working on the light assembly or door switch.
Steps to restore interior light:
- 1. Confirm door switch operation: Check if the control panel reacts when the door is opened (e.g., display changes). If not, test the door reed switch as described in the door sensor fault entry.
- 2. Access LED module: Remove the interior light cover (usually clipped or screwed in). Inspect the LED board for burn marks or discoloration.
- 3. Check connections: Ensure the light module connector is firmly seated. Reseat it if loose.
- 4. Test LED module: If you have a low-voltage DC source, briefly power the LED module to confirm it lights. If not, replace it with a "STAIGIS LED light module" for your model.
- 5. Reassemble and test: Plug the unit back in and verify that the light now turns on with the door.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
LED Light Module
Check Price on Amazon
We may earn a commission from links on this page.