Excessive Vibration / Noise
Wine cooler makes loud humming, rattling, or vibrating noises during operation.
Advertisements
Possible Causes
Unit not leveled on floor, Loose internal fan mounting, Vibrating copper refrigerant lines touching cabinet, Noisy compressor mounts
How to Fix / Troubleshooting
Safety first: Unplug the unit before adjusting internal components. Avoid bending refrigerant lines sharply.
Steps to reduce noise:
- 1. Level the cabinet: Use a bubble level and adjust the STAIGIS leveling feet so the unit is stable and does not rock.
- 2. Check for external contact: Ensure the cabinet is not touching walls, cabinets, or other appliances that can transmit vibration.
- 3. Inspect internal fans: Remove interior panels and verify that the evaporator fan is securely mounted and not hitting wiring or plastic shrouds. Tighten screws and reposition wires as needed.
- 4. Isolate refrigerant lines: At the rear, gently separate any copper lines that are touching each other or the cabinet. Use foam sleeves or rubber grommets to prevent metal-to-metal contact.
- 5. Check compressor mounts: Ensure the rubber grommets under the compressor are intact. Replace worn "compressor mounting grommets" if necessary.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Evaporator Fan Motor