Sub-Zero Single Zone Failure – Zone Fan or Damper Issue

Dual‑zone wine cooler has one zone cooling properly while the other zone is warm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan in warm zone, Stuck or failed air damper, Faulty zone thermistor, Zone control board failure

How to Fix / Troubleshooting

Safety first: Disconnect power before removing interior panels.

Step 1 – Compare zones

  • Note which zone is warm and whether its fan runs when the compressor is on.

Step 2 – Access warm zone evaporator

  • Remove shelves and the rear panel of the warm zone.
  • Check for ice blocking the evaporator or fan.

Step 3 – Test fan and damper

  • If the fan does not run, replace the evaporator fan motor.
  • If equipped with a damper and it does not move or is stuck closed, replace the damper assembly.

Step 4 – Sensor and board

  • Replace the zone thermistor if readings are inaccurate.
  • If components test good, the zone control board may be faulty and require professional replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements