EC26
Sub-Zero
Door Switch / Door Status Fault
Wine cooler displays EC26 and may show issues with door status; interior lights or fans may not behave correctly.
Advertisements
Possible Causes
Failed magnetic reed door switch, Misaligned door magnet, Broken or pinched door switch wiring, Faulty input on main control board
How to Fix / Troubleshooting
Safety first: Disconnect power before removing trim or switch assemblies.
Step 1 – Check door switch behavior
- Open and close the door while observing the interior lights and fan operation.
- If lights stay on with the door closed or never come on, the door switch circuit may be faulty.
Step 2 – Inspect door gasket and alignment
- Ensure the door closes squarely and fully against the cabinet.
- Check that the door magnet (if used) is present and aligned with the switch location.
Step 3 – Locate and test door switch
- Depending on model, the switch may be in the cabinet frame or integrated into the hinge area.
- Remove the switch or trim cover and inspect wiring for damage.
- Reseat the connector and test operation again.
Step 4 – Replace door switch
- If the switch is physically damaged or does not change state when the door is opened/closed, replace it with the correct Sub‑Zero door switch.
Step 5 – Control board check
- If a new switch does not resolve EC26, the main control board input may be defective and require professional service.
Advertisements
Repair Difficulty
Easy
2/5