dE
Summit
Door Switch / Door Ajar Detection Fault
Wine cooler display shows dE or a door icon; interior light may stay on and cooling may stop.
Advertisements
Possible Causes
Failed magnetic reed switch or mechanical door switch, Misaligned door magnet, Broken switch wiring in cabinet frame, Faulty control board door input
How to Fix / Troubleshooting
Safety: Unplug the unit before working around the door frame wiring.
- Check door closure: Ensure nothing is blocking the door and that it closes flush with the cabinet.
- Inspect door magnet: Many Summit wine coolers use a magnet in the door and a reed switch in the frame. Verify the magnet is still embedded in the door edge and not missing.
- Locate door switch: Look along the cabinet frame for a small plastic switch or hidden reed switch behind a plastic cover.
- Test switch: With a multimeter, check continuity while opening and closing the door. Replace the door switch / reed switch if it does not change state.
- Adjust door alignment: If the door is sagging, adjust hinges so the magnet aligns properly with the switch area.
- Control board: If the switch and magnet are good but dE persists, the main control board may misread the door input and require replacement.