Teka
Unresponsive Keypad / Touch Control
Control panel buttons do not respond or respond intermittently; temperature cannot be adjusted.
Advertisements
Possible Causes
Stuck or worn buttons, Moisture ingress in control panel, Loose interface cable, Faulty user interface PCB
How to Fix / Troubleshooting
Safety: Disconnect power before removing the control panel.
- Clean panel surface: Wipe the control panel with a soft, slightly damp cloth to remove sticky residues that may cause buttons to stick. Do not spray cleaner directly onto the panel.
- Dry moisture: If condensation is visible under the panel, remove it and allow it to dry completely.
- Check cable connections: Reseat the ribbon cable or harness between the user interface and main PCB.
- Replace interface board: If buttons remain unresponsive, replace the user interface PCB with a Teka-compatible part.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
User Interface / Keypad PCB
Check Price on Amazon