CF
Teka Compressor Failure or Control Fault

Display shows CF and the compressor does not run; unit remains warm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open compressor winding, Locked compressor, Failed compressor relay on PCB, Wiring fault to compressor

How to Fix / Troubleshooting

Safety warning: Disconnect power before accessing the compressor or control board. Refrigerant system work must be done by certified personnel.

  • Check wiring: Inspect the harness from the main control PCB to the compressor start components for loose or burnt connectors.
  • Test compressor windings: With the unit unplugged, remove the compressor terminal cover and measure resistance between terminals. Open or shorted windings indicate a failed compressor.
  • Inspect PCB relay: Access the main control PCB and check the compressor relay for signs of burning or mechanical failure. If the relay is defective, replace the PCB.
  • Professional compressor replacement: If the compressor is electrically or mechanically failed, contact a refrigeration technician to recover refrigerant, replace the compressor, and recharge the system.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon

We may earn a commission from links on this page.