E8
Teka
User Interface / Display Board Communication Fault
Wine cooler shows E8 and the display may be blank or flicker; buttons may not respond correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose display board connector, Damaged ribbon cable, Faulty display PCB, Faulty main control PCB communication circuit
How to Fix / Troubleshooting
Safety: Disconnect the appliance from mains before removing the control panel.
- Access the control panel: Remove the screws securing the top/front control panel of the Teka wine cooler. Carefully pull the panel forward.
- Inspect connectors: Check the ribbon cable or harness between the display board and the main control PCB. Reseat all connectors firmly.
- Check for moisture or corrosion: Look for signs of condensation or liquid ingress on the display PCB. If present, dry the board thoroughly and clean light corrosion with isopropyl alcohol and a soft brush.
- Visual inspection: Examine the display board for burnt components, cracked solder joints, or damaged tracks.
- Test operation: Reassemble temporarily, restore power, and see if E8 clears and the display functions normally.
- Replace faulty board: If the issue persists, replace the user interface/display PCB with a Teka-compatible part. If a new display board does not resolve the fault, the main control PCB may also need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface / Display PCB
Check Price on Amazon
We may earn a commission from links on this page.