E17
Thermador Zone Damper / Air Diverter Fault (Dual-Zone Models)

E17 error; dual-zone unit may show both zones at same temperature or one zone disabled.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck or failed air damper motor, Broken damper flap, Obstructed air channel between zones, Faulty control board damper output

How to Fix / Troubleshooting

Safety: Unplug the unit before removing interior panels.

Steps:

  • Identify damper location: On dual-zone Thermador wine coolers, the damper is typically located between the upper and lower compartments behind an interior panel.
  • Access damper: Remove shelves and the partition or rear panel to expose the damper assembly.
  • Inspect for obstruction: Check for bottles, packing material, or ice blocking the air channel or damper flap. Remove any obstructions and defrost ice with towels and ambient air.
  • Test damper movement: With power restored briefly, change zone setpoints and listen/feel for damper movement. Then disconnect power again.
  • Electrical test: Check damper motor resistance and wiring continuity. Replace the damper assembly if the motor is open or the flap is broken.
  • Control board: If the damper tests good but never receives power, the main control board may be at fault.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Damper Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements