dF
Transtherm
Defrost Mode Indication / Defrost Cycle Active
Display alternates between temperature and dF; unit may pause cooling periodically
Advertisements
Possible Causes
Normal automatic defrost cycle, Extended defrost due to heavy frost buildup, Faulty defrost sensor or control logic if dF persists
How to Fix / Troubleshooting
Safety: No immediate hazard; this is often a normal indication. Unplug the unit before removing panels.
Steps:
- Observe duration: If dF appears briefly and then returns to normal temperature display, it is likely a standard defrost cycle and requires no repair.
- Check for frost: If dF remains for hours and cooling is poor, inspect the evaporator area for heavy ice buildup. Defrost manually by unplugging and leaving the door open until all ice melts.
- Inspect defrost sensor: Verify the evaporator sensor is correctly attached to the coil and wiring is intact.
- Monitor after reset: After a full manual defrost and restart, if dF still persists abnormally, the control board or sensor may be faulty and should be tested or replaced.
Warning: Do not chip ice with sharp tools; you can puncture refrigerant lines.
Advertisements
Repair Difficulty
Easy