Transtherm
Interior LED Lighting Failure
Interior light does not turn on when the door is opened
Advertisements
Possible Causes
Failed LED light module, Faulty or misaligned door switch, Broken wiring to light, Control board not supplying voltage to light circuit
How to Fix / Troubleshooting
Safety: Unplug the cabinet before working on the light or door switch.
Steps:
- Check settings: Some Transtherm models allow disabling the light. Verify that the light is not turned off via the control panel.
- Inspect door switch: Locate the door switch (plunger or magnetic reed). Press it manually and see if the light flickers. Replace the door switch if it feels loose or does not actuate.
- Check LED module: Remove the light cover and inspect the LED module for burn marks or water damage. Replace the interior LED light module if defective.
- Verify wiring: Ensure the light harness is connected firmly to the control board.
Note: LED modules are low voltage but still require the unit to be unplugged during service.