E0
TYLZA
Main Control Board Communication Fault
Display shows E0 and the wine cooler will not cool or respond to temperature changes.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose wiring harness between display PCB and main control board, Failed main control board, Failed display/control PCB, Power surge damage to low-voltage circuit
How to Fix / Troubleshooting
Safety first: Unplug the TYLZA wine cooler from the wall outlet before removing any panels. Do not work on live circuits.
- Power reset: Unplug the unit for 5–10 minutes, then plug it back in. Check if E0 clears.
- Inspect control connections: Remove the front control panel (usually held by screws from inside the door trim). Verify the ribbon cable and wiring harness between the display PCB and the main control board are fully seated and not pinched or corroded.
- Check main control board: Access the rear lower compartment, remove the back cover, and visually inspect the main control board for burnt spots, swollen capacitors, or corrosion.
- Reconnect and test: Reseat all connectors on the main control board and display PCB one by one, then restore power and see if the error clears.
- If E0 persists: Replace the main control board first (most common), then the display/control PCB if needed. Use a TYLZA-compatible board matched to your exact model.