E3
TYLZA Ambient Temperature Sensor Failure

Display shows E3 and the compressor cycles erratically or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ambient NTC sensor near front grille, Sensor wiring damaged by vibration, Loose connector on main control board, Sensor out of calibration due to moisture ingress

How to Fix / Troubleshooting

Safety: Disconnect power before working near the compressor compartment.

  • Locate ambient sensor: On many TYLZA wine coolers, the ambient sensor is mounted near the front kick plate or behind the front grille to sense room temperature.
  • Visual inspection: Remove the kick plate, locate the small probe or sensor housing, and check for broken wires or corrosion.
  • Check resistance: With a multimeter, measure the sensor resistance at room temperature. Compare to the specification in the service manual if available; open or short readings indicate failure.
  • Replace sensor: Install a compatible ambient NTC sensor, secure it in the same location, and ensure the wiring is not touching hot compressor lines.
  • Reconnect and test: Plug the unit back in and verify that E3 clears and the compressor now cycles normally.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.