Hi
TYLZA High Temperature Limit / Sensor Over-Range

Display shows Hi and the temperature cannot be adjusted higher or reads extremely high.

Advertisements

Possible Causes

Cabinet sensor open-circuit, Disconnected sensor harness, Sensor damaged by pulling or pinching, Control board interpreting open sensor as 'Hi'

How to Fix / Troubleshooting

Safety: Disconnect power before working inside the cabinet.

  • Inspect sensor wiring: Locate the cabinet temperature sensor and follow its wiring to the main control board. Look for breaks or loose connectors.
  • Test sensor: Use a multimeter to check for continuity and resistance. Infinite resistance indicates an open sensor.
  • Reconnect or replace: Reseat the connector or replace the sensor with a TYLZA-compatible part if open.
  • Test operation: Restore power and verify that the display shows a realistic temperature and 'Hi' clears.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Cabinet Temperature Sensor
Check Price on Amazon