TYLZA Insufficient Cooling / Partial Loss of Refrigerant Charge

Wine cooler runs but does not get cold enough; temperatures stay above setpoint in both zones.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak in evaporator or tubing, Weak compressor, Severely dirty condenser coil, Condenser fan not moving enough air

How to Fix / Troubleshooting

Safety: Do not attempt sealed system repairs yourself. Focus on airflow and basic checks.

  • Verify settings: Confirm both zones are set to the desired temperatures and not in demo or energy-saving mode.
  • Check door seal: Inspect the door gasket for gaps or tears. Replace if it does not seal all around.
  • Clean condenser: Unplug the unit, remove the rear cover, and clean the condenser coil and fan thoroughly.
  • Check fans and compressor: With the cover off and power restored, verify that the compressor and both fans run when cooling is demanded.
  • Observe frost pattern: Remove the interior rear panel and check the evaporator coil. If only a small section frosts or there is no frost, a sealed system issue is likely and requires a professional technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Sealed System (Evaporator/Compressor)
Check Price on Amazon