TYLZA Overcooling Due to Sensor or Control Failure

Wine cooler runs continuously and gets too cold, sometimes freezing bottles even at higher setpoints.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Cabinet temperature sensor out of calibration, Sensor not in correct location, Stuck compressor relay on main control board, Control board logic fault

How to Fix / Troubleshooting

Safety: Disconnect power before accessing sensors or the control board.

  • Verify setpoint: Ensure the temperature is not set too low for wine storage.
  • Check with thermometer: Place an accurate thermometer inside to confirm actual temperature versus display.
  • Inspect sensor placement: Make sure the cabinet sensor is not touching the evaporator or a cold wall; reposition if necessary.
  • Replace sensor: If readings are inaccurate, replace the cabinet NTC sensor with a TYLZA-compatible part.
  • If compressor never cycles off: The main control board relay may be stuck. Replace the main control board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cabinet Temperature Sensor
Check Price on Amazon