Possible Causes
Zone-specific NTC sensor failure, Faulty air damper or fan between zones, Partial blockage in dual evaporator system, Zone relay failure on PCB
How to Fix / Troubleshooting
Safety first: Unplug the cooler before accessing internal panels or the control board.
Steps to check and fix:
- 1. Compare zones: Verify setpoints and actual temperatures in both zones with separate thermometers.
- 2. Check zone sensor: Test the NTC sensor for the affected zone and replace if out of specification.
- 3. Inspect inter-zone fan or damper: On models that share cooling between zones, check the fan or motorized damper that directs air to the affected zone. Ensure it operates and is not blocked.
- 4. PCB outputs: If the hardware is good, the zone control relay or triac on the main PCB may have failed. Replace the main control PCB if necessary.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Zone Air Circulation Fan / Damper
Check Price on Amazon