H1
Vestfrost
High Temperature Warning (Cabinet Over-Temperature)
Display shows H1 or flashes maximum temperature; interior is warm; alarm may sound.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Door left open or frequently opened, Ambient temperature too high for appliance class, Blocked condenser or failed condenser fan, Compressor or sealed system fault
How to Fix / Troubleshooting
Safety first: Ensure the unit is placed in an environment within the specified ambient temperature range for your Vestfrost model.
Steps to check and fix:
- 1. Check door usage: Make sure the door is fully closed and not obstructed by shelves or bottles. Minimize door openings to allow temperature to recover.
- 2. Inspect door gasket: Look for tears, warping, or dirt on the gasket. Clean with warm soapy water and dry. Replace if it does not seal all around.
- 3. Verify ventilation and condenser cleanliness: Ensure adequate clearance around the cooler. Clean dust from the condenser coil and ventilation grilles.
- 4. Check condenser fan and compressor: Confirm that both run when cooling is required. If the fan is not running, test and replace it. If the compressor is hot and cycling on overload, suspect a mechanical or electrical compressor issue.
- 5. Allow recovery time: After correcting airflow and door issues, allow 12–24 hours for the temperature to drop. The H1 warning should clear automatically.
- 6. If temperature does not drop: Persistent high temperature despite proper operation suggests a sealed-system problem (leak, restriction, or weak compressor). Contact a certified technician.
Advertisements