Vestfrost Cabinet Air Circulation Failure

Interior fan does not run; cold spots near evaporator and warm spots elsewhere.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan motor, Ice blocking fan, Broken fan blades, Faulty fan control on PCB

How to Fix / Troubleshooting

Safety first: Unplug the cooler before accessing the fan area. Beware of sharp metal edges.

Steps to check and fix:

  • 1. Confirm fan not running: With the door switch held closed and compressor running, listen for fan noise. Then unplug before proceeding.
  • 2. Access fan: Remove the interior rear panel to expose the fan and evaporator.
  • 3. Clear ice and obstructions: Defrost any ice and ensure the fan blades spin freely.
  • 4. Test and replace fan: Check motor resistance and replace the evaporator fan motor if open or seized.
  • 5. PCB control: If a new fan does not run, the control board may not be supplying power and may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements