Vestfrost Temperature Calibration / Sensor Drift

Temperature display is inaccurate; actual wine temperature is significantly different from the displayed value.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aging NTC sensors, Poor sensor placement, Firmware calibration offset, Partial sensor wiring damage increasing resistance

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing sensors or the control board.

Steps to check and fix:

  • 1. Verify with reference thermometer: Place a calibrated thermometer in the center of the cabinet and compare readings after several hours of stable operation.
  • 2. Check sensor mounting: Ensure cabinet sensors are properly mounted and not touching very cold surfaces directly.
  • 3. Replace suspect sensors: If readings are consistently off by several degrees, replace the cabinet NTC sensors with new Vestfrost-compatible parts.
  • 4. Control calibration: Some models allow minor temperature offset adjustments via the control panel; consult the manual. If not, and the error is large, the control PCB may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.