Possible Causes
Misaligned door magnet and reed switch, Weak door hinges causing sag, Faulty door switch, Control board misinterpreting door signal
How to Fix / Troubleshooting
Safety first: Unplug the unit before adjusting the door switch or accessing wiring.
Steps to correct:
- 1. Check door alignment: Ensure the door is level and square with the cabinet. Adjust leveling legs or hinge screws to correct sagging.
- 2. Inspect magnet and switch alignment: Verify that the door magnet lines up directly with the reed switch in the frame when closed. Adjust the magnet position if possible.
- 3. Test door switch: Replace the reed switch if it intermittently opens when the door is closed.
- 4. Control board check: If alignment and switch are good but alarms persist, the main control board may be faulty and require replacement.