Viking False Door Ajar Alarm

Door alarm sounds frequently even though the door appears closed and sealed.

Advertisements

Possible Causes

Misaligned door magnet and reed switch, Weak door hinges causing sag, Faulty door switch, Control board misinterpreting door signal

How to Fix / Troubleshooting

Safety first: Unplug the unit before adjusting the door switch or accessing wiring.

Steps to correct:

  • 1. Check door alignment: Ensure the door is level and square with the cabinet. Adjust leveling legs or hinge screws to correct sagging.
  • 2. Inspect magnet and switch alignment: Verify that the door magnet lines up directly with the reed switch in the frame when closed. Adjust the magnet position if possible.
  • 3. Test door switch: Replace the reed switch if it intermittently opens when the door is closed.
  • 4. Control board check: If alignment and switch are good but alarms persist, the main control board may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch (Reed Switch and Magnet)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements