Viking
Single-Zone Cooling Failure in Dual-Zone System
Dual-zone Viking wine cooler: one zone cools properly while the other is too warm.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator fan in warm zone, Air damper stuck closed between zones, Separate sensor failure in affected zone, Control board not energizing zone components
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing interior panels or fans.
Steps to diagnose:
- 1. Compare zones: Verify setpoints and actual temperatures in both zones with thermometers.
- 2. Listen for fans: With power on (initial check), listen for fan operation in both zones. Then unplug before opening panels.
- 3. Access warm zone evaporator: Remove shelves and rear panel in the affected zone to inspect the fan and evaporator.
- 4. Check fan and damper: Ensure the fan spins freely and the air damper (if present) is not stuck closed. Replace the fan motor if it does not run.
- 5. Test zone sensor: Measure resistance of the temperature sensor for the warm zone and replace if out of spec.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Zone Evaporator Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements