This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Air damper between zones stuck open, Control board not regulating zones separately, Sensor wiring crossed or misconnected, Failed zone sensor
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing interior panels or the control board.
Steps to correct:
- 1. Verify configuration: Confirm the model is truly dual-zone and not a single-zone with two displays.
- 2. Inspect air damper: Access the partition between zones and check the damper mechanism. Ensure it moves freely and is not stuck open.
- 3. Check sensors: Verify each zone has its own sensor and that wiring is correctly connected to the control board.
- 4. Control board evaluation: If dampers and sensors are correct, the main control board may have lost independent zone control and require replacement.