Viking Cabinet Overheating / Poor Ventilation

Exterior sides or top of the wine cooler feel very hot to the touch.

Advertisements

Possible Causes

Blocked ventilation grills, Condenser coil heavily clogged, Condenser fan not running, Unit installed in a tight enclosure without proper clearances

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning coils or accessing the rear compartment.

Steps to correct:

  • 1. Check installation clearances: Verify that the wine cooler has the side, rear, and top clearances specified by Viking. Move the unit or modify cabinetry if necessary.
  • 2. Clean condenser coil: Remove the rear lower panel and vacuum or brush the condenser coil thoroughly.
  • 3. Verify condenser fan operation: With power restored, ensure the fan runs whenever the compressor is on. Replace the fan motor if it is not operating.
  • 4. Inspect door gasket: A leaking door can cause the unit to run excessively, heating the cabinet walls. Replace the gasket if needed.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.