Viking
Short Cycling / Control or Sensor Issue
Wine cooler cycles on and off very frequently (short cycling).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Temperature sensor located too close to evaporator outlet, Oversensitive control algorithm, Poor air circulation around sensor, Control board relay chatter
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing sensors or the control board.
Steps to mitigate:
- 1. Verify ambient conditions: Ensure the unit is not installed in an area with rapidly fluctuating room temperature or direct sunlight.
- 2. Check sensor placement: Confirm the cabinet sensor is in its proper location and not directly in the cold air stream from the evaporator outlet.
- 3. Improve airflow: Avoid blocking interior vents with bottles or shelves.
- 4. Control board replacement: If short cycling persists and sensors are correctly placed, the main control board may be malfunctioning and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature Sensor (NTC Probe)
Check Price on Amazon