Viking
Continuous Run / Inefficient Cooling or Control Fault
Wine cooler runs continuously and rarely shuts off, even when set temperature is reached.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coil, Door gasket leaking, Low refrigerant charge, Misreading temperature sensor or control board
How to Fix / Troubleshooting
Safety first: Unplug the unit before cleaning or accessing components.
Steps to address:
- 1. Clean condenser coil: Remove rear panel and thoroughly clean the coil.
- 2. Inspect door gasket: Replace if it does not seal tightly.
- 3. Check temperature sensor: Test and replace the cabinet sensor if it reads incorrectly.
- 4. Evaluate sealed system (professional): If the unit still runs continuously and cannot reach setpoint, a refrigerant leak or restriction may exist. Contact a Viking-authorized technician.
Advertisements
Repair Difficulty
Medium
3/5
Advertisements