Viking Temperature Display Inaccuracy

Wine cooler temperature display is inaccurate compared to an internal thermometer.

Advertisements

Possible Causes

Aging or drifting temperature sensor, Sensor not in correct location, Control board calibration drift, Poor air circulation around sensor

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing sensors or the control board.

Steps to improve accuracy:

  • 1. Verify with multiple thermometers: Place at least two accurate thermometers in different locations inside the cabinet to confirm actual temperature.
  • 2. Check sensor placement: Ensure the cabinet sensor is properly clipped to the liner or in its designated well, not dangling or touching the evaporator coil.
  • 3. Replace sensor: If the sensor is old or readings are inconsistent, replace the cabinet temperature sensor with a Viking-compatible part.
  • 4. Control calibration: Some models allow a small temperature offset adjustment in service mode. If available, adjust according to the service manual.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Cabinet Temperature Sensor (NTC Probe)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements