E9
Vinotemp
Evaporator/Interior Fan Motor Fault
Wine cooler shows E9 and interior fan does not run or runs intermittently; cooling is uneven.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator fan motor, Fan blade obstructed by ice or wiring, Faulty fan driver circuit on control board
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing the interior fan. Fan blades can be sharp.
Steps to fix E9 (fan fault):
- 1. Access the interior fan: Remove the interior rear panel to expose the evaporator and fan assembly.
- 2. Check for obstructions: Look for ice buildup, loose wires, or insulation blocking the fan blades. Clear any obstructions and ensure the fan spins freely by hand.
- 3. Test the fan motor: With the unit unplugged, disconnect the fan connector and measure resistance across the motor leads. An open circuit indicates a failed motor.
- 4. Apply test voltage (advanced): If you are experienced and have a suitable low-voltage DC supply (for DC fans), briefly power the fan to confirm operation. Do not exceed rated voltage.
- 5. Replace the fan motor: Install a Vinotemp-compatible evaporator or interior circulation fan. Ensure the fan is oriented correctly for airflow and that wires are secured away from the blades.
- 6. Reassemble and test: Reinstall panels, restore power, and verify that the fan runs when the compressor or cooling module is active. The E9 code should clear.
Note: If the fan tests good but does not receive power, the control board fan driver may be defective.