Er
Vinotemp
General Control Error / Undefined Fault
Display shows Er or ERR and unit may not cool or respond properly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Transient control glitch, Incorrect voltage supply, Internal control board failure
How to Fix / Troubleshooting
Safety first: Disconnect power before inspecting internal components.
Steps to handle Er/ERR:
- 1. Hard reset: Unplug the wine cooler for at least 10 minutes. Plug back in and observe if the error returns.
- 2. Check power source: Verify the outlet voltage with a multimeter (typically 110–120V AC in North America). Avoid using power strips or long extension cords.
- 3. Inspect control board: Remove the rear electronics cover and visually inspect the main PCB for burnt spots, cracked solder joints, or loose connectors.
- 4. Reseat all connectors: Disconnect and reconnect all harnesses to ensure good contact.
- 5. Replace control board: If the error persists and no specific sensor or component fault is found, replace the main control board with the correct Vinotemp part.
Note: Document the model and serial number before ordering a replacement board to ensure compatibility.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon