Vinotemp Cooling Drive Failure with Active Fans

Interior fan runs but compressor or Peltier module does not, and temperature rises.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor, Open Peltier module, Faulty relay or triac on control board

How to Fix / Troubleshooting

Safety first: Unplug the unit before testing electrical components.

Steps to troubleshoot:

  • 1. Listen for compressor: If the fan runs but the compressor is silent and not vibrating, suspect a compressor or start device issue.
  • 2. Test start relay/overload: Replace the start device if it is burnt or rattles.
  • 3. Measure compressor current draw: Using a clamp meter (advanced), check if the compressor is drawing current when commanded on. No current suggests an open winding or control issue.
  • 4. Test Peltier module (if applicable): Measure resistance and replace if open.
  • 5. Inspect control board outputs: If the compressor/module is good but never receives power, replace the main control board.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon