Vinotemp No Cooling / Compressor or Module Not Starting

Wine cooler does not cool at all; interior stays at room temperature and compressor or Peltier module is not running.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay or overload, Open Peltier module, Faulty main control board, Open thermal fuse in cooling circuit

How to Fix / Troubleshooting

Safety first: Unplug the cooler before testing electrical components. High voltage is present in the compressor circuit.

Steps to diagnose no cooling:

  • 1. Confirm power: Verify the outlet works by plugging in another device. Check that the cooler's power cord and plug are intact.
  • 2. Listen for operation: After plugging in, listen for the compressor hum or fan noise. If completely silent, suspect the control board or power circuit.
  • 3. Check control settings: Ensure the unit is not in standby mode and that the set temperature is below room temperature.
  • 4. Inspect compressor start device (compressor models): Remove the rear cover and locate the start relay/overload on the compressor. Remove it and shake gently; if it rattles or shows burn marks, replace it with a Vinotemp-compatible start device.
  • 5. Test Peltier module (thermoelectric models): Measure resistance across the module; replace if open or shorted.
  • 6. Check for blown thermal fuse: Some models include a thermal fuse in series with the cooling module. Test for continuity and replace if open.
  • 7. Replace main control board: If the compressor or module and start components test good but never receive power, the control board is likely faulty.

Warning: Compressor replacement and refrigerant handling must be done by a licensed technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay
Check Price on Amazon

We may earn a commission from links on this page.