Whirlpool Lower Zone Cooling Failure

Upper zone cools properly but lower zone is warm (dual-zone model).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed lower zone evaporator fan, Blocked air channel between zones, Lower zone thermistor failure, Partial refrigerant restriction affecting lower circuit

How to Fix / Troubleshooting

Safety: Unplug the unit before removing interior panels.

Steps:

  • Check settings: Verify that the lower zone setpoint is lower than ambient and not turned off.
  • Inspect airflow: Remove lower zone shelves and panels to check for blocked air passages.
  • Test lower zone fan: With panels removed, briefly power the unit and observe if the lower zone fan runs when cooling is demanded. Unplug again before touching anything.
  • Replace fan motor: If the fan does not run and has proper voltage, replace the Whirlpool-compatible lower zone evaporator fan motor.
  • Check lower thermistor: Test and replace the lower zone thermistor if it reads incorrectly.
  • Sealed system: If fans and sensors are good but the lower zone never cools, a sealed system issue may exist and requires professional service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Lower Zone Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements