Whirlpool Poor Cooling Performance / Airflow or Load Issue

Wine cooler is running but interior temperature is too warm and cannot reach setpoint.

Advertisements

Possible Causes

Dirty condenser coil, Blocked air vents inside cabinet, Overloaded with bottles restricting airflow, Failing evaporator fan motor

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning coils or accessing fans.

Steps:

  • Check temperature setting: Ensure the setpoint is low enough for desired storage temperature.
  • Inspect bottle loading: Avoid stacking bottles tightly against the rear wall or blocking internal vents; allow space for air circulation.
  • Clean condenser coil: Remove the rear access panel and gently brush or vacuum dust from the condenser coil.
  • Verify fan operation: Confirm that both the condenser fan (rear) and evaporator fan (inside behind panel) run when the compressor is on.
  • Replace faulty fan: If a fan is not running and receives power, replace the Whirlpool-compatible fan motor.
  • Allow time to stabilize: After adjustments and cleaning, allow 12–24 hours for the temperature to stabilize.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements