Whynter Continuous Run / Control Feedback Failure

Compressor and fans run continuously without shutting off, even when set temperature is reached.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty temperature sensor, Stuck compressor relay on control board, Poor door seal causing constant heat gain

How to Fix / Troubleshooting

Safety: Unplug the unit before testing sensors or accessing the control board.

Steps:

  • Verify actual temperature: Use an independent thermometer to confirm the cabinet temperature. If it is at or below setpoint but the unit keeps running, a control issue is likely.
  • Inspect door gasket: Ensure a tight seal all around the door. Replace the gasket if leaking.
  • Test temperature sensors: Check resistance of cabinet and evaporator thermistors. Replace any that are out of specification.
  • Check control board: If sensors and gasket are good, the compressor relay may be stuck closed. Replace the main control board.

Note: Continuous running increases wear and energy use; address promptly.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon