Wine Enthusiast Compressor Short Cycling / Overload Trip

Wine Enthusiast wine cooler fans run but the compressor cycles off quickly and the unit does not cool.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak compressor start capacitor (if equipped), Failing start relay, High head pressure from dirty condenser, Internal compressor mechanical fault

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing compressor components. Capacitors can hold a charge.

  • Clean condenser: Ensure condenser coils are clean and the condenser fan is working to reduce compressor load.
  • Inspect start components: Remove the compressor cover and check the start relay and any start capacitor for bulging, burning, or cracking.
  • Test and replace: Use a multimeter to test the relay and capacitor according to specifications. Replace with Wine Enthusiast-compatible parts if out of range.
  • Monitor operation: After replacement, observe compressor run time. If it still shuts off quickly and becomes very hot, the compressor itself may be failing.

Compressor replacement is a sealed system repair and should be performed by a certified technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay / Start Capacitor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements