E8
Wolf LED Lighting Circuit Error

Display shows E8 and the interior LED lighting may not function or may flicker.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted LED light module, Failed LED driver on control board, Loose light harness connector, Overloaded low-voltage circuit

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before accessing light modules.

  • Inspect LED modules: Remove interior trim to access LED strips or modules. Look for burn marks or discoloration.
  • Disconnect modules: Unplug LED modules one at a time and restore power briefly to see if E8 clears. The module that triggers the error when connected is likely defective.
  • Check connectors: Ensure all light harness connectors are fully seated and not corroded.
  • Replace faulty module: Install the correct Wolf LED module and avoid mixing different types in the same circuit.
  • If all modules test good: The LED driver on the main control board may be faulty and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

LED Light Module
Check Price on Amazon