E10 displayed, interior light may flicker; control panel may be unresponsive or reset intermittently.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Disconnect the appliance from mains before inspecting power connections. Only qualified persons should work on live circuits.
Steps:
- Check wall outlet: Test the outlet with another appliance to ensure stable power. Avoid using multi-way adaptors or long extension leads.
- Inspect mains cable: Look for cuts, kinks, or burn marks on the Zanussi wine cooler's power cord. Replace the cord if damaged.
- Verify terminal block: Remove the rear panel and locate the mains terminal block or entry point on the PCB. Ensure screws are tight and there is no discoloration or melting.
- Look at PCB power section: Inspect the low-voltage power supply area on the main board for bulging capacitors or burnt components.
- Replace main PCB if needed: If external power is stable and connections are sound, but E10 persists, the internal power supply on the PCB is likely faulty and the board should be replaced.
Note: If you experience frequent power fluctuations at home, consider using a surge protector rated for refrigeration appliances.
Repair Difficulty
Required Part